Part Number Hot Search : 
103KA DZ10B TDA4580 SEF106B AE10737 B80C800 SP7500 T2D221
Product Description
Full Text Search
 

To Download HDBB-105W-AG Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  linear power supplies data sheet mcd10016 rev. 1.2, 13-nov-09 page 1 of 9 www.power-one.com power-one produces the industry?s broadest selection of linear power supplies with output voltages from 5 volts through 250 volts. rugged technology and proven design merge to create quiet, highly-regulated, dependable dc power. the linear power supplies are approved to domestic and international regulatory standards, and are ce marked to the low voltage directive (lvd). ? rohs compatible for all six substances ? worldwide ac input capabilities: 100/120/220/230/240 vac ? 0.05% output regulation ? low output ripple ? ul, csa, and tv approvals ? mean time before failure (mtbf) in excess of 300,000 hours ? ce marked to low voltage directive ? 100% burn-in ? 2 year warranty ? overvoltage protection (ovp) standard on 5v single outputs, optional for other outputs under 48v features description overvoltage protection options these optional overvoltage protection modules are offered for use with power-one?s linear power supplies. each is user adjustable from 6.4v to 34v. ovp selection guide model case size ovp modules required single b,c,n,d (1) ovp-12g output e,f (1) ovp-24g dual aa,b,bb,cc (1) ovp-12g protects both outputs output e (1) ovp-24g protects both outputs triple aa,baa,d (1) ovp-12g protects both 12v output cbb, 131 through 15v outputs dbb,dcc peak n,baa,cbb current 131 (1) ovp-12g protects any output models not provided with built-in ovp note: outputs with factory built-in ovp are indicated in the voltage/current rating chart for each model. ovp is not available for 48v through 250v models. ovp-12g ovp-24g overvolt age protection options
mcd10016 rev. 1.2, 13-nov-09 page 2 of 9 www.power-one.com linear power supplies data sheet (see additional features column) a overvoltage protection, set at 6.2 v 0.4 v. b non-adjustable 3-terminal regulator. c remote sense provided. d with output inhibit and parallel operation master/slave capability. e with output inhibit. f adjustable 3-terminal regulator. g can be made into an isolated output by removing jumper w1. h model requires 100 lfm forced-air cooling above 75% of rated output power at 50 degrees c. case dimensions type (inches) aa 6.50 x 4.00 x 2.10 b 4.87 x 4.00 x 2.10 baa 10.25 x 4.00 x 2.95 bb 7.00 x 4.87 x 2.95 c 5.62 x 4.87 x 2.95 cbb 11.00 x 4.87 x 3.28 cc 9.38 x 4.87 x 3.28 cp131 11.00 x 4.87 x 3.28 d 9.00 x 4.87 x 3.28 dbb 14.25 x 4.87 x 3.38 dcc 15.00 x 4.88 x 4.55 e 14.00 x 4.87 x 3.53 f 16.75 x 4.88 x 5.00 n 7.00 x 4.87 x 3.28 case dimensions type (millimeters) aa 165.10 x 101.60 x 53.34 b 123.70 x 101.60 x 53.34 baa 260.35 x 101.60 x 74.93 bb 177.80 x 123.70 x 74.93 c 142.75 x 123.70 x 74.93 cbb 279.40 x 123.70 x 83.31 cc 238.25 x 123.70 x 83.31 cp131 279.40 x 123.70 x 83.31 d 228.60 x 123.70 x 83.31 dbb 361.95 x 123.70 x 85.85 dcc 381.00 x 123.95 x 115.57 e 355.60 x 123.70 x 89.66 f 425.50 x 123.95 x 127.00 n 177.80 x 123.70 x 83.31 nominal max model input case additional vout* amps 100 to 264 vac type features & notes 5vout 5 1.5 ha5-1.5/ovp-ag b a 5 3 hb5-3/ovp-ag b a, c 5 6 hc5-6/ovp-ag c a, c 5 9 hn5-9/ovp-ag n a, c 5 12 hd5-12/ovp-ag d a, c 5 18 he5-18/ovp-ag e a, c 5 25 f5-25/ovp-ag f a, c, d, h 5 35 g5-35/ovp-ag f a, c, d, h 5 50 cp197-ag f a, c, d 12 to 15vout 12 0.9 ha15-0.9-ag b 12 1.7 hb12-1.7-ag b c 12 3.4 hc12-3.4-ag c c 12 5.1 hn12-5.1-ag n c 12 6.8 hd12-6.8-ag d c 12 10.2 he12-10.2-ag e c 12 16 f15-15-ag f c, d, h 15* 0.9 ha15-0.9-ag b 15 1.5 hb15-1.5-ag b c 15 3 hc15-3-ag c c 15 4.5 hn15-4.5-ag n c 15 6 hd15-6-ag d c 15 9 he15-9-ag e c 15* 15 f15-15-ag f c, d, h 24 to 28vout 24 0.5 ha24-0.5-ag b 24 1.2 hb24-1.2-ag b c 24 2.4 hc24-2.4-ag c c 24 3.6 hn24-3.6-ag n c 24 4.8 hd24-4.8-ag d c 24 7.2 he24-7.2-ag e c 24 12 f24-12-ag f c, d, h 28* 0.5 ha24-0.5-ag b 28 1 hb28-1-ag b c 28 2 hc28-2-ag c c 28 3 hn28-3-ag n c 28 4 hd28-4-ag d c 28 6 he28-6-ag e c 28* 10 f24-12-ag f c, d, h 48vout 48 0.5 hb48-0.5-ag b 48 1 hc48-1-ag c 48 3 hd48-3-ag d c 48 4 he48-4-ag e c * may require jumpering or potentiometer adjustment. unsigned output voltages are isolated and can be used as either + or - polarities. model numbers highlighted in yellow or shaded are not recommended for new designs.
nominal max model input case additional vout* amps 100 to 264 vac type features & notes 5v to 15vout +5, ?5 1.5, 1.5 haa5-1.5/ovp-ag aa a +5, ?5 3, 3 hbb5-3/ovp-ag bb a +5, ?5 6, 6 hcc5-6/ovp-ag cc a, c 5, 12 to 15 2, 0.5 haa512-ag aa a 5, 12 to 15 3, 1.25 hbb512-ag bb a, c 5, 12 to 15 6, 2.5 hcc512-ag cc a, c +12, ?5* 1, 0.4 haa15-0.8-ag aa c +12, ?5* 1.7, 0.7 hbb15-1.5-ag bb c +12, ?12 0.4, 0.4 had12-0.4-ag b b +12, ?12 1, 1 haa15-0.8-ag aa c +12, ?12 1.7, 1.7 hbb15-1.5-ag bb c +12, ?12 3.4, 3.4 hcc15-3-ag cc c +12, ?12* 5, 5 hdd15-5-ag e c +12, ?15* 1, 0.8 haa15-0.8-ag aa c +12, ?15* 1.7, 1.5 hbb15-1.5-ag bb c +12, ?15* 3.4, 3 hcc15-3-ag cc c +12, ?15* 5, 5 hdd15-5-ag e c +15, ?5* 0.8, 0.4 haa15-0.8-ag aa c +15, ?5* 1.5, 0.7 hbb15-1.5-ag bb c +15, ?12* 0.8, 1 haa15-0.8-ag aa c +15, ?12* 1.5, 1.7 hbb15-1.5-ag bb c +15, ?12* 3, 3.4 hcc15-3-ag cc c 15, ?12* 5, 5 hdd15-5-ag e c 15v to 24vout +15, ?15 0.4, 0.4 had15-0.4-ag b b +15, ?15 0.8, 0.8 haa15-0.8-ag aa c +15, ?15* 1.5, 1.5 hbb15-1.5-ag bb c +15, ?15* 3, 3 hcc15-3-ag cc c +15, ?15 5, 5 hdd15-5-ag e c +24, ?24 0.6, 0.6 haa24-0.6-ag aa +24, ?24 1.2, 1.2 hbb24-1.2-ag bb +24, ?24 2.4, 2.4 hcc24-2.4-ag cc c linear power supplies data sheet mcd10016 rev. 1.2, 13-nov-09 page 3 of 9 www.power-one.com (see additional features column) a overvoltage protection, set at 6.2 v 0.4 v. b non-adjustable 3-terminal regulator. c remote sense provided. d with output inhibit and parallel operation master/slave capability. e with output inhibit. f adjustable 3-terminal regulator. g can be made into an isolated output by removing jumper w1. h model requires 100 lfm forced-air cooling above 75% of rated output power at 50 degrees c. case dimensions type (inches) aa 6.50 x 4.00 x 2.10 b 4.87 x 4.00 x 2.10 baa 10.25 x 4.00 x 2.95 bb 7.00 x 4.87 x 2.95 c 5.62 x 4.87 x 2.95 cbb 11.00 x 4.87 x 3.28 cc 9.38 x 4.87 x 3.28 cp131 11.00 x 4.87 x 3.28 d 9.00 x 4.87 x 3.28 dbb 14.25 x 4.87 x 3.38 dcc 15.00 x 4.88 x 4.55 e 14.00 x 4.87 x 3.53 f 16.75 x 4.88 x 5.00 n 7.00 x 4.87 x 3.28 case dimensions type (millimeters) aa 165.10 x 101.60 x 53.34 b 123.70 x 101.60 x 53.34 baa 260.35 x 101.60 x 74.93 bb 177.80 x 123.70 x 74.93 c 142.75 x 123.70 x 74.93 cbb 279.40 x 123.70 x 83.31 cc 238.25 x 123.70 x 83.31 cp131 279.40 x 123.70 x 83.31 d 228.60 x 123.70 x 83.31 dbb 361.95 x 123.70 x 85.85 dcc 381.00 x 123.95 x 115.57 e 355.60 x 123.70 x 89.66 f 425.50 x 123.95 x 127.00 n 177.80 x 123.70 x 83.31 unsigned output voltages are isolated and can be used as either + or - polarities. * may require jumpering or potentiometer adjustment.
nominal max model input case additional vout* amps 100 to 264 vac type features & notes triple output models, 5v to 24vout +5, +12, ?5* 2, 0.4, 0.4 htaa-16w-ag aa a 5, +12, ?5* 3, 1, 0.4 hbaa-40w-ag baa a, c +5, +12, ?5* 6, 1, 0.4 hcaa-60w-ag d a, c 5, +12, ?5* 6, 1.7, 0.7 hcbb-75w-ag cbb c 5, +12, ?5* 8, 1.7, 0.7 cp131-ag cp131 a, c 5, +12, ?5* 12, 1.7, 0.7 HDBB-105W-AG dbb a, c 5, +12, ?12 2, 0.4, 0.4 htaa-16w-ag aa a 5, +12, ?12 3, 1, 1 hbaa-40w-ag baa a, c +5, +12, ?12 6, 1, 1 hcaa-60w-ag d a, c 5, +12, ?12 6, 1.7, 1.7 hcbb-75w-ag cbb c 5, +12, ?12 8, 1.7, 1.7 cp131-ag cp131 a, c 5, +12, ?12 12, 1.7, 1.7 HDBB-105W-AG dbb c 5, +12, ?12 12, 3.4, 3.4 hdcc-150w-ag dcc a, c 5, +12, ?15* 2, 0.4, 0.4 htaa-16w-ag aa a 5, +12, ?15* 3, 1, 0.8 hbaa-40w-ag baa a, c +5, +12, ?15* 6, 1, 1 hcaa-60w-ag d a, c 5, +12, ?15 6, 1.7, 1.5 hcbb-75w-ag cbb c 5, +12, ?15 8, 1.7, 1.5 cp131-ag cp131 a, c 5, +12, ?15* 12, 1.7, 1.5 HDBB-105W-AG dbb c 5, +12, ?15 12, 3.4, 3 hdcc-150w-ag dcc a, c 5, +15, ?5* 2, 0.4, 0.4 htaa-16w-ag aa a 5, +15, ?5* 3, 0.8, 0.4 hbaa-40w-ag baa a, c +5, +15, ?5* 6, 1, 0.4 hcaa-60w-ag d a, c 5, +15, ?5* 6, 1.5, 0.7 hcbb-75w-ag cbb c 5, +15, ?5* 8, 1.5, 0.7 cp131-ag cp131 a, 5, +15, ?5* 12, 1.5, 0.7 HDBB-105W-AG dbb c 5, +15, ?12* 2, 0.4, 0.4 htaa-16w-ag aa a 5, +15, ?12* 3, 0.8, 1 hbaa-40w-ag baa a, c +5, +15, ?12* 6, 1, 1 hcaa-60w-ag d a, c 5, +15, ?12 6, 1.5, 1.7 hcbb-75w-ag cbb c 5, +15, ?12 8, 1.5, 1.7 cp131-ag cp131 a, c 5, +15, ?12* 12, 1.5, 1.7 HDBB-105W-AG dbb c 5, +15, ?12 12, 3, 3.4 hdcc-150w-ag dcc a, c 5, +15, ?15* 2, 0.4, 0.4 htaa-16w-ag aa a 5, +15, ?15* 3, 0.8, 0.8 hbaa-40w-ag baa a, c +5, +15, ?15* 6, 1, 1 hcaa-60w-ag d a, c 5, +15, ?15 6, 1.5, 1.5 hcbb-75w-ag cbb c 5, +15, ?15 8, 1.5, 1.5 cp131-ag cp131 a, c 5, +15, ?15* 12, 1.5, 1.5 HDBB-105W-AG dbb c 5, +15, ?15 12, 3, 3 hdcc-150w-ag dcc a, c case dimensions type (inches) aa 6.50 x 4.00 x 2.10 b 4.87 x 4.00 x 2.10 baa 10.25 x 4.00 x 2.95 bb 7.00 x 4.87 x 2.95 c 5.62 x 4.87 x 2.95 cbb 11.00 x 4.87 x 3.28 cc 9.38 x 4.87 x 3.28 cp131 11.00 x 4.87 x 3.28 d 9.00 x 4.87 x 3.28 dbb 14.25 x 4.87 x 3.38 dcc 15.00 x 4.88 x 4.55 e 14.00 x 4.87 x 3.53 f 16.75 x 4.88 x 5.00 n 7.00 x 4.87 x 3.28 mcd10016 rev. 1.2, 13-nov-09 page 4 of 9 www.power-one.com linear power supplies data sheet (see additional features column) a overvoltage protection, set at 6.2 v 0.4 v. b non-adjustable 3-terminal regulator. c remote sense provided. d with output inhibit and parallel operation master/slave capability. e with output inhibit. f adjustable 3-terminal regulator. g can be made into an isolated output by removing jumper w1. h model requires 100 lfm forced-air cooling above 75% of rated output power at 50 degrees c. case dimensions type (millimeters) aa 165.10 x 101.60 x 53.34 b 123.70 x 101.60 x 53.34 baa 260.35 x 101.60 x 74.93 bb 177.80 x 123.70 x 74.93 c 142.75 x 123.70 x 74.93 cbb 279.40 x 123.70 x 83.31 cc 238.25 x 123.70 x 83.31 cp131 279.40 x 123.70 x 83.31 d 228.60 x 123.70 x 83.31 dbb 361.95 x 123.70 x 85.85 dcc 381.00 x 123.95 x 115.57 e 355.60 x 123.70 x 89.66 f 425.50 x 123.95 x 127.00 n 177.80 x 123.70 x 83.31 unsigned output voltages are isolated and can be used as either + or - polarities. * may require jumpering or potentiometer adjustment.
linear power supplies data sheet mcd10016 rev. 1.2, 13-nov-09 page 5 of 9 www.power-one.com input specifications parameter conditions/description min nom max units input voltage - ac jumper selectable, shipped factory configured for 100 vac tap 87 100 110 (note 1, 2) 120vac operation. all models must be externally 120 vac tap 104 120 132 vac fused for proper operation. fuse ratings are marked 220 vac tap 191 220 242 on each unit. consult factory for each unit?s fuse 240 vac tap 209 240 264 requirements. input frequency ac input. 47 63 hz line regulation output voltage charge for a 10% line change: f case models. -0.01 +0.01 had12, had15. -1.0 +1.0 % outputs with adjustable three terminal regulators. -0.5 +0.5 all other models. -0.05 +0.05 notes: 1) derate output current 10% for 50hz operation. 2) input voltage tolerance for 230vac operation is +15%, -10%. output specifications parameter conditions/description min nom max units output adjustment minimum output adjustment range (note 1). -5 +5 % efficiency 5 volt outputs. 45 12 volt and 15 volt outputs. 55 % 24 volt and higher outputs. 60 f case models. 3.0 mv pk-pk ripple and noise 5 volt, 12 volt, and 15 volt models. 5.0 mv pk-pk (note 2) all three terminal regulator outputs. 0.2 % pk-pk 24 volt through 250 volt models. 3.0mv pk-pk plus 0.02% of output voltage, max load regulation output change for a 50% load change: f case models. -0.02 +0.02 had12, had15. -1 +1 % outputs with adjustable three terminal regulators. -0.5 +0.5 all other models. -0.05 +0.05 transient response recovery time, to within 1% of initial set point due to a 50% load change. 50 s notes: 1) output voltage adjustments: output voltage adjustments can be made to within 5% of factory setting of nominal output voltage. locate the ?vadj? potentiometer on the power supply pcb and use a screwdriver to adjust the output pot. the had12 and had15 3 terminal regulator outputs are not adjustable. 2) full load, 20mhz bandwidth. safety, regulatory, and emi specifications parameter conditions/description min nom max units agency approvals ul60950-1. csa 60950-1 ?cul?. approved en60950-1. iec60950-1. dielectric withstand input to output. 3000 v ac voltage input to ground. 1500 electromagnetic fcc cfr title 47 part 15 sub-part b - conducted. interference en55022 / cispr 22 conducted. compatible with system compliance to level b. en55022 / cispr 22 radiated. leakage current per en60950 (264vac) 23 50 a interface signals and internal protection parameter conditions/description min nom max units overvoltage protection provided on 5 volt output units where indicated. 5.8 6.6 v other outputs may use optional overvoltage protectors ovp-12 and ovp-24. remote sense total voltage compensation for cable losses with respect to the main output. 250 mv provided on models where indicated. overcurrent/short circuit automatic current limit/foldback. rated as a percentage of output power. 115 120 140 % protection master/slave operation for parallel operation of up to 6 units. master/slave pin provided on f case models only. contact factor y for application notes.
mcd10016 rev. 1.2, 13-nov-09 page 6 of 9 www.power-one.com linear power supplies data sheet environmental specifications parameter conditions/description min nom max units operating temperature derate output power linearly above 50c by 3% per c. at 100% load 0 50 c at 40% load 70 c storage temperature -40 85 c temperature coefficient 0c to 50c (after 15 minute warm-up). 0.1 0.3 %/c 24 hours after warm-up. -0.3 +0.3 % shock operating. 20 g pk vibration random vibration from 10 hz to 2 khz, 3 axis. 6.15 g rms relative humidity non-condensing. 5 95 %rh
linear power supplies data sheet mcd10016 rev. 1.2, 13-nov-09 page 7 of 9 www.power-one.com
mcd10016 rev. 1.2, 13-nov-09 page 8 of 9 www.power-one.com linear power supplies data sheet
linear power supplies data sheet mcd10016 rev. 1.2, 13-nov-09 page 9 of 9 www.power-one.com nuclear and medical applications - power-one products are not designed, intended for use in, or authorized for use as critical c omponents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written conse nt of the respective divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of HDBB-105W-AG

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X